I really don't know what's wrong :/ cause the spell is completely independent on casting/animation time since it procs on "unit starts the effect of an ability" event
what exactly happens when you cast it?
keep in mind it's in vJass so you'll need Jasshelper to compile it (from NewGen)
you could try posting ur map and I'll see what's wrong
also, make sure to put [ljass]private constant function DURATION takes integer level returns real[/ljass] and everything below that line at the top of your scope...forgot to mention...
forgot to mention in the pm, TAF is my main map library, so that's why those variables h and hi have TAF_ in front of them. much like those GT functions have GT_ in the front.
Of course you can implement it
I am just not completely sure everything works properly :S
If you implement it, do you think you could do an extensive test of it for me, please ?
That'd be REALLY helpful !
And for the implementation, you should just need to create a new trigger, convert it to custom text, and copy in the code there.
Then, there is quite a few constants which you might want to take a look at, so you know it works like you want it to
There is especially one constant you might wanna change, and that is the one called something like "HAVE_HEROES_ON_INIT"
If this one is true, the system will select one hero from each player, which will act like their swap hero, but if it's false, yourself need to (Sometime during the game, and before anyone has swapped) set "SwapData[<Insert player-id of each player here>].swapHero" to the unit each player should use to swap with
Hope you understood this, if not then just send me a PM or something
And then I have to set up an arduino board to read those sensors, which I also don't know very much about but I have a whole bunch of crash course things for that
Another issue I'm learning is that a lot of the air quality sensors don't work at very high ambient temperatures. I'm planning on heating this enclosure to like 60C or so, and that's the upper limit of their functionality
Although I don't know if I need to actually actively heat it or just let the plate and hotend bring the ambient temp to whatever it will, but even then I need to figure out an exfiltration for hot air. I think I kind of know what to do but it's still fucking confusing
I don't think I'm dealing with quite the same pressures though, at the very least its a significantly smaller system. For the time being I'm just going to put together a quick scrubby box though and hope it works good enough to not make my house toxic
I do know this - xenforo dropped the ball by not keeping the vbulletin reputation comments as a feature. The loss of the Reputation comments data when we switched to Xenforo really was the death knell for the site when it came to all the users that left. I know I missed it so much and I got way less interested in the site when that feature was gone and I run the site.